Quote:
Pack designers on the other hand adjust the current capability by adjusting the number of cells in parallel. Energy density in this instance stays constant and capacity increases. Heat, fast charge/discharge, and the state you leave your battery at have the most impact on cycle life and irreversible capacity loss. Most battery manufactures ship batteries between 25-50 percent state of charge to maximize battery life and safety. |
|
![]() |
![]() |